Adjustments and Settings
3. Place a strip of masking tape over the
hole on the left side of the Focus
Carriage.
4. The red diode beam should appear
on the tape. The red diode beam
should be fairly centered over the
hole.
5. Using the Focus Feature (1) of the Viewer Tab in the UCP, verify the position of
the red diode beam relative to the hole in the focus carriage in all four corners of
the table.
6. The red diode should be fairly centered on the hole in all four corners of the table. If
this is the case, you can remove the masking tape from the hole in the focus
carriage and reinstall the optics. The red diode is aligned.
7. If the red diode beam is not centered on the hole in all four corners of the table, the
beam will need to be aligned. Do not remove the masking tape or reinstall the optics.
8. Power off the PLS and unplug the unit.