Westerbeke 120D-TWO Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Motor Westerbeke 120D-TWO herunter. Full resolution Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Table of Contents

GO TO Table of Contents 16008 North 81st Street • Scottsdale, Arizona 85260 • 480.483.1214 • www.ulsinc.com PRELIMINARY 03-

Seite 2

Adjustments and Settings A010 – Laser Power Upgrading Table of Contents The PLS3.60, PLS4.60, and PLS6.60 is capable of upgrading to a maximum of 6

Seite 3

Adjustments and Settings A020 - CPU Initialization / Auto-Z Calibration NOTE: This procedure must be performed with the solid aluminum Engraving Tab

Seite 4 - [email protected]

Adjustments and Settings 4. Click on the Calibrate button within the Lens Size box of the System Tab. The following window appears. Click on Save

Seite 5 - Service P

Adjustments and Settings A030 - Cutting Table Calibration Table of Contents Installation 1. Turn the PLS on and lower the table all the way down t

Seite 6 - A000 – Safety – PLEASE READ!

Adjustments and Settings A040 - Rotary Calibration Table of Contents 1. Turn on the UCP and PLS. 2. Open the top door. 3. Lower the table about

Seite 7 - Laser Safety

Adjustments and Settings 10. Now, use the Z Axis buttons (3) or the Z Axis Menu on your keypad (recommended) to move the table up and down and use t

Seite 8

Adjustments and Settings A050 - X-axis Arm Alignment Check and Adjust (Squaring) Table of Contents 1. Power off the PLS and unplug it. 2. Remov

Seite 9

Adjustments and Settings Adjustment 6. Locate the Y-axis couplers (1). For each of the two couplers, there are two screws that mount it to the Y-m

Seite 10 - A010 – Laser Power Upgrading

Adjustments and Settings ults. A060 - Laser Beam Check and Alignment Table of Contents Verify the table is clear of any objects that could obstruct

Seite 11

Adjustments and Settings 3. Place a strip of masking tape over the hole on the left side of the Focus Carriage. 4. The red diode beam should appea

Seite 12 - Adjustments and Settings

Table of Contents Help 0000 - Contact the ULS Technical Support Department 0010 - Performing Professional Series Service Procedures Adjustments and

Seite 13

Adjustments and Settings 9. Slowly move the X-axis arm (1) forward. 10. Locate and carefully remove the large thumb screw securing the cover on th

Seite 14 - A040 - Rotary Calibration

Adjustments and Settings Note: To create a small burn mark on the tape in the next step you will need to adjust your Power and Seconds settings in t

Seite 15

Component Removal and Replacement R000 – Focusing Lens Table of Contents 1. Make sure the PLS is powered OFF and unplugged. 2. Open the top d

Seite 16

Component Removal and Replacement R010 – #3 Mirror Table of Contents 1. Make sure the PLS is powered OFF and unplugged. 2. Open the top door

Seite 17

Component Removal and Replacement R020 - #2 Mirror Table of Contents Note: Be careful not to touch the #2 Mirror. 1. Make sure the VLS is powered

Seite 18

Component Removal and Replacement R100 - Rear Cover Table of Contents 1. Power off the PLS. 2. Walk around to the back of the laser machine. 3.

Seite 19

Component Removal and Replacement R110 - Top Door/Window Table of Contents Obtain assistance from 1 or 2 additional people when removing the top

Seite 20

Component Removal and Replacement 6. Locate the 12 window nuts and remove them with needle nose pliers like shown. Set the window nuts aside. 7

Seite 21

Component Removal and Replacement R130 – Rulers Table of Contents 1. To replace the rulers you need to remove all 5 screws and set them aside. 2

Seite 22 - R000 – Focusing Lens

Component Removal and Replacement R200 - X-axis Bearings Table of Contents 1. Power OFF and unplug the PLS. 2. Open the top door and bring the

Seite 23 - R010 – #3 Mirror

Electronics R500 - Laser R510 - CPU R520 - Keypad R530 - Upper Flex Board R540 - Lower Flex Board R550 - Thermal Sensor Board R560 - Thermal

Seite 24 - R020 - #2 Mirror

Component Removal and Replacement 6. Grab a hold of the Focus Carriage and gently push up then tilt forward to remove the Focus Carriage from the

Seite 25 - R100 - Rear Cover

Component Removal and Replacement R210 - X-axis Belt Table of Contents 1. Power OFF and unplug the PLS. 2. Remove #2 mirror cover by removing

Seite 26 - R110 - Top Door/Window

Component Removal and Replacement 6. Using a stapler, attach one end of the old belt (2) to one end of the new belt 1). Do not overlap the belt

Seite 27

Component Removal and Replacement 11. Push the focus carriage all the way to the left and push the belt clamp all the way to the right, on the X-a

Seite 28 - R130 – Rulers

Component Removal and Replacement R220 - X-Axis Idler Pulley Table of Contents 1. Power OFF and unplug the PLS. 2. Remove #2 mirror cover by

Seite 29 - R200 - X-axis Bearings

Component Removal and Replacement R230 - X-Axis Motor and Drive Gear Table of Contents 1. Power Off and unplug the PLS. 1. Remove #2 mirror c

Seite 30

Component Removal and Replacement 4. Remove the other mounting screw (5) is on the front side of the motor housing with a 3/32 Allen wrench. Lift

Seite 31 - R210 - X-axis Belt

Component Removal and Replacement *If you plan on replacing the motor do not install the new drive gear or retaining clap at this time. 7. Position

Seite 32

Component Removal and Replacement R240 - X-Axis Arm Table of Contents NOTE: Place any hardware removed from the laser machine in a safe place. 1.

Seite 33

Component Removal and Replacement 5. Unscrew the two protruding screws on the right side of the X-Axis Arm. One screw is located in front of t

Seite 34 - R220 - X-Axis Idler Pulley

Help 0000 – ULS Technical Support Department Table of Contents Technical Support Department 16008 North 81st Street Scottsdale, AZ 85260 Ph

Seite 35

Component Removal and Replacement R300 - Y-Axis Belts Table of Contents Take note of the current tension of the Y-Axis Belt by using your thumb an

Seite 36

Component Removal and Replacement 7. Insert the new Y-Axis Belt ends into the belt clamp with the belts teeth facing inward. The Y-Axis belt in th

Seite 37 - X-Axis Motor

Component Removal and Replacement R310 - Y-Axis Idler Pulleys Table of Contents Take note of the current tension of the Y-Axis Belt by using your

Seite 38 - R240 - X-Axis Arm

Component Removal and Replacement R320 - Y-Axis Drive Gear Table of Contents 1. Power OFF and unplug the PLS. 2. Remove the X-Axis Arm. 3. R

Seite 39

Component Removal and Replacement 7. Rotate the long shaft with one hand to locate the Y-Axis Drive Gear clamp screw. Loosen but do not remove the

Seite 40 - R300 - Y-Axis Belts

COMPONENT REMOVAL AND REPLACEMENT R330 - Y-Axis Bearings Table of Contents 1. Power OFF and unplug the PLS. 2. Remove the X-Axis Arm. 3. Set t

Seite 41

Component Removal and Replacement R340 - Y-Axis Motor Table of Contents 1. Power OFF and unplug the PLS. 2. Open the top door and push the X-Ax

Seite 42 - R310 - Y-Axis Idler Pulleys

Component Removal and Replacement 5. Loosen, but do not remove, the coupler screws that attach the motor to the Y-shafts. Slide the couplers out

Seite 43 - R320 - Y-Axis Drive Gear

Component Removal and Replacement R400 - Z-Axis Motor Table of Contents When performing this procedure, make sure that you do not accidentally tur

Seite 44

Component Removal and Replacement 5. Hold the Z-Axis Motor while unscrewing the 3 screws that hold the Z-Axis Motor in place. Set the screws and

Seite 45 - R330 - Y-Axis Bearings

Help 0010 – Performing Service P able of Contents rocedures afety erforming the procedures in this manual, always be sure to read and understand iff

Seite 46 - R340 - Y-Axis Motor

Component Removal and Replacement R410 – Z-Axis Board Replacement Table of Contents 1. If the laser machines table is raised, lower it all the way

Seite 47

Component Removal and Replacement 5. Unplug all 3 connectors from the board. 6. When installing the new board verify that the 2 white nylon stan

Seite 48 - R400 - Z-Axis Motor

Component Removal and Replacement R500 - Laser Table of Contents Handle the laser with care! Do not bump or jar it. 1. Make sure the PLS is

Seite 49

Component Removal and Replacement R510 - CPU Driver Board(s) Replacement Table of Contents 1. Disconnect the power to the laser machine. NOTE: Th

Seite 50

Component Removal and Replacement 5. Gently pull the driver card straight up with both hands. 6. When installing the new board verify that the boa

Seite 51

Component Removal and Replacement R520 – Keypad Table of Contents 1. Make sure the PLS is powered OFF and unplugged. 2. Open the top door. 3

Seite 52 - R500 - Laser

Component Removal and Replacement 6. Pop the keypad assembly off from its 6 metal standoffs. DO NOT pull on the keypad as it is still attached b

Seite 53

Component Removal and Replacement R530 - Upper Flex Board Table of Contents 1. Power OFF and unplug the PLS. 2. Remove the X-Axis Motor Module

Seite 54

Component Removal and Replacement R540 - Lower Flex Board Table of Contents 1. Power OFF and unplug the PLS. 2. Open the top door and push the

Seite 55 - R520 – Keypad

Component Removal and Replacement 4. Unscrew the 2 screws that hold the board in place. 5. Grab a hold of the Lower Flex Board and turn it aroun

Seite 56

Adjustments and Settings A000 – Safety – PLEASE READ! Table of Contents Description of Appropriate Use This device is designed for laser cutting an

Seite 57 - R530 - Upper Flex Board

Component Removal and Replacement R550 – Thermal Sensor Board Table of Contents 1. Make sure the PLS is powered OFF and unplugged. 2. Press the

Seite 58 - R540 - Lower Flex Board

Component Removal and Replacement 4. Disconnect the two white connectors first then the black connector on the board. Move the wires aside. 5.

Seite 59

Component Removal and Replacement R560 – Thermal Snap Switch Table of Contents Verify that the battery is reinstalled into the PLS in order for th

Seite 60 - R550 – Thermal Sensor Board

Component Removal and Replacement 5. Bend the metal contacts inward to expose the hex nuts. 6. Remove the hex nuts to release the Thermal Sensor

Seite 61

Component Removal and Replacement R570 - Power Supply(s) Table of Contents PLS 3.60 & 4.60 1. Power OFF and unplug the PLS. 2. Proceed to th

Seite 62 - R560 – Thermal Snap Switch

Component Removal and Replacement 6. The Power Supply connectors are located between the Power Supply Module and CPU Module. Disconnect the 2 la

Seite 63

Component Removal and Replacement PLS 6.60 & 6.120D CARE SHOULD BE TAKEN WHEN MOVING OR LIFTING THE POWER SUPPLY. Obtain assistance from 1 or 2

Seite 64 - R570 - Power Supply(s)

Component Removal and Replacement 5. Unscrew the 2 screws located on the back of the PLS near the Exhaust Ports that hold the power supplies in p

Seite 65

PHOTOS P0010 - Front View Table of Contents 1. FOCUS CARRIAGE 2. #2 MIRROR 3. BEAM WINDOW 4. THERMAL SENSOR 5. ENGRAVING TABLE 6. X-ARM

Seite 66

PHOTOS P0020 - Rear View, Laser Tube Installed Table of Contents 1. LASER TUBE 2. LASER ELECTRICAL CONNECTOR 3. REAR COVER 4. TOP DOOR

Seite 67

Adjustments and Settings • Care should be taken when moving or lifting this device. Obtain assistance from 3 or 4 additional people when lifting or

Seite 68

PHOTOS P0030 - Rear View, Laser Tube Removed Table of Contents 1. CPU* 2. 48VDC POWER SUPPLY* (PLS3.60, 4.60, 6.60 – ONE SUPPLY, PLS6.120D

Seite 69

PHOTOS P0040 - Left and Right Side Views, PLS3.60, 4.60, 6.60 Table of Contents NPUT C6. THERMAL SENSOR BATT1. AC POWER I ONNECTOR URE G

Seite 70

PHOTOS P0050 – Left and Right Side Views, PLS6.120D Table of Contents 1. USB CONNECTION 2. THERMAL SENSOR BATTERY 3. AC POWER INPUT CON

Seite 71

Adjustments and Settings A005 - Computer Power Management Configuration Table of Contents Power management is an option on computers and monitors t

Seite 72

Adjustments and Settings 5. Select the tab “Power Schemes”. 6. For the “Settings for Home/Office Desk power scheme” box, select “Never” for all t

Kommentare zu diesen Handbüchern

Keine Kommentare