Problem
Engine stops.
(continued)
Battery
is
not
charging.
Battery runs down.
Westerbeke
Diesel
Engines
Probable Cause
Transmission failure.
Alternator drive
Circuit Breaker.
High resistance
leak
to
the ground.
Low resistance
leak
to
ground.
Alternator.
Preheat solenoid.
56
Verification/Remedy
Check the fluid
level in the
transmission. Transmission
seizure will stop the engine.
Engine will not turn over
by engaging the starter.
Check drive
belt tension.
Be
sure the alternator turns
freely. Check
for
loose
connections. Check output
with a voltmeter. Ensure that
12
Volts are present at the
EXC connection. Check the
alternator as described on
page 39.
Observe if the gauges and
panel lights are activated
when the engine
is
not running.
Test the
Circuit Breaker.
Check wiring.
Insert a
sensitive (0-.25 Amp) Amp
meter in the battery
lines.
(Do not start the engine.)
Remove connections and
replace after the short
Is
located.
Check
all wires for
temperature rise to
locate
the fault.
Disconnect the alternator
at the output after a good
battery charging.
If the
leakage stops, remove the
alternator and bench test
~.
Repair
or
replace the unn.
Test the preheat solenoid
with a voltmeter on the
lead
to
the thermostart device.