Electrical System
The
electrical system should be checked
to
ensure that all wiring harnesses are tied down properly with
clamps
or
plastic ties, spaced at intervals close enough
to
prevent chafing from vibration. Check to ensure
that
all the engine's harness connections are tight and that they are connected to the appropriate terminals.
IWARNINGI
Do not smoke
or
allow an open flame near batteries. Lead acid batteries emit hydrogen, a
highly-explosive gas. Turn off the emergency switch
in
the positive line
of
battery.
Make sure the positive (
+ ) battery connection is connected
to
the battery connection
of
the starting solenoid.
The negative
(-)
battery connection should be connected
to
the system ground (the engine block).
~WARNINGI
When servicing the battery
or
checking the electrolyte level, wear rUbber gloves, a rubber
apron, and eye protection. Battery acid may
splash on the skin
or
into the eyes inadvertent-
ly
when removing electrolyte caps.
Check
level and specific gravity
of
battery electrolyte to ensure maximum engine starting efficiency. Make
sure
terminals are clean and tight.
Ventilation
The ventilation requirements of the engine
include the following: combustion air
Is
required for the engine's
cylinders and ventilating air
is
required
to
clear the bilges below the engine, as well as the compartment
in
which the engine is located, of engine heat and potentially toxic and flammable diesel fumes. Refer
to
the
"SPECIFICATIONS" section of this manual for airflow requirements, page
8.
21