Westerbeke WPDS-20 Betreibershandbuch Seite 55

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 114
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 54
Problem
START
switch
Is
de-
pressed:
no
starter
engagement.
(continued)
No
ignition; engine
cranks
but
does not
start.
Failure
to
stop.
Engine stops.
Probable Cause
Loose battery
connection.
Low battery
voltage.
Shut-off lever.
Faulty
fueling system.
Shut-off
linkage is
disconnected.
Fuel starvation.
Fuel contamination.
55
Verification/Remedy
Check battery
connections.
Check voltage present at
the solenoid
S terminal when
the
START button
is
depressed.
Return shut-off lever to
the RUN position.
1.
Check for fuel
to
the
engine.
2.
Check for air in the fuel
system. Bleed the fuel
system.
3.
Fuel lift pump is faulty.
4.
Filters are clogged.
(Replace filters and bleed
the fuel system.)
Stop engine
by
manually
moving the
RUN
linkage
to
STOP. That failing,
shut off fuel and air. Loosen high
pressure lines
to
the injectors.
RPM
fluctuation before
stopping.
Check for fuel
blockage, clogged filters,
or
air in the fuel system.
Suddenly stops. Fuel
contamination damaging
the fuel injection pump.
Clean the filter and bleed
the fuel system_
Check
fuel delivery to the injectors.
Westerbeke
Diesel
Engines
Seitenansicht 54