MAINTENANCE AND ADJUSTMENTS
Introduction
This section contains a scheduled preventive maintenance program and several adjustment procedures the
owner/operator can perform without the benefit
of
sophisticated and expensive tools and instruments.
Preventive
Maintenance
Perform the preventive maintenance
in
accordance with the schedules listed in the following paragraphs.
Adherence
to
these schedules will ensure the equipment is maintained in the best possible condition and
that it will perform
to
expectations. Those items marked
by
an asterisk
(*)
are recommended
to
be per-
formed
by
an authorized dealer
or
distributor.
Daily
(before
each
use)
1.
Check the oil sump level. Maintain the oil level at
or
near upper level mark on dipstick.
2.
Check the coolant level in the plastic recovery tank. Maintain this level at
or
above the level marked
ADD.
3.
Visually inspect the unit; check for loose belts, chafed
or
broken wires, loose brackets and fittings,
damaged hoses, loose clamps, and other equipment not properly secured.
4.
Check the fuel supply. Fill tank(s) with a good grade of
No.2
diesel fuel, if required.
5.
Check the primary filter/water separator. Drain and service as required.
(A
primaryfilter/water separator
is optional, but strongly recommended.)
6.
Check the generator's gauges
or
lights
for
proper oil pressure, operating temperature, and starting bat-
tery charging voltage once the engine is operating.
7.
Check the generator's output meters (when installed) for proper AC voltage and output frequency.
Monthly
Check the condition
of
the zinc anode in the heat exchanger's sea water circuit. Clean
or
replace the anode,
as required. Keep the area inside the heat exchanger clean of zinc anode debris.
Servicing
After
Initial
50
Hours
of
Operation
1.
Change the engine's lubrication oil and oil filter.
2.
Replace the fuel filter element in the electric fuel lift pump and in the engine-mounted secondary fuel fil-
ter. Change the fuel filter element and clean the optional filter/water sedimentor, if a separator has been
installed, and if the model type permits cleaning.
*3. Torque the cylinder head bolts.