Westerbeke BCD 4.4KW Betreibershandbuch Seite 62

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 94
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 61
Load
Connections
The generator's data plate gives the voltage, current and frequency rating
of
the generator. An AC wiring
decal is
affb<ed
to
the inside
of
the louvered cover on the generator end. A diagram
of
the various AC volt-
age connections is provided on the decal.
The generator is a single-phase, reconnectable 120 Volts AC two-wire
or
120/240 Volts AC three-wire, at
60
Hertz;
or
110 Volts AC two-wire, 110/220 Volts AC three-wire,
or
220 Volts AC two-wire, at
50
Hertz. Refer
to
the "SYSTEM SPECIFICATIONS" section
of
this manual
for
generator ratings, page
11
for
the BCD 4.4KW,
and page 15
for
the BCD 6.0KW.
NOTE: The frame ground wire must be moved when changing from 110 Volts, 50 Hertz
to
/220
Volts, 50 Hertz.
A circuit breaker should be installed between the generator and the
AC load. This circuit breaker should be
rated
at
120%
of
the generator's AC output and be able
to
react quickly
to
overloads, subject
to
motor start-
hig considerations.
N
N
L2
N
L2
Lt
r
1
~4
J:::l
3
1 4
3-
1
4e::::::=-3
5e2-
~
6
5 2
6e
5.2-6
L1
L1
L
t
N
N
110v
50
Hz
120v 60 Hz
220v
50Hz
240v
60Hz
220v
50Hz
For making connections
to
the AC terminal block, use terminal ends
for
#10
studs which will accept multi-
strand wire sized
for
the number
of
conductors in the bundle, the rating
of
the conductor's insulation, and
amperage that will be drawn through the conductor(s). (Refer
to
the generator's data plate
for
the gener-
ator's amperage and voltage ratings.)
NOTE: When changing Hertz produced
by
the generator, an engine speed adjustment at the
governor/fuel solenoid linkage must be made. The
AC output connections on the above il-
lustrated terminal blocks must be selected for the voltage and Hertz
to
be produced. A plug
at the capacitor must be changed
for
50(#5)
or
60(#6) Hertz use. Early models with 3 wire
connections
to
the integral controller require a 50(#5)
or
60(#6) Hertz connection change at
the bridge rectifier in the
DC charging circuit. Refer
to
the "Generator's Internal Wiring
Schematic" on page 54.
59
Westerbeke Generators
Seitenansicht 61