Antifreeze
Concentration
Freezing
Temperature
ANTIFREEZE CONCENTRATION
DATA
%
13
23
30
35
45
50
60
, F
23
14
5
-4
-22 -40
-58
('
C)
(-5) (-10) (-15)
(-20)
(-30) (-40) (-58)
NOTE:
An
antifreeze concentration should be selected on the basis
of
a temperature which
is about
10' F (5'
C)
lower than the actual atmospheric temperature expected.
B. Filling the Fresh Water System
A coolant recovery tank kit
is
supplied with each Westerbeke gasoline generator. The purpose of this
recovery tank
Is
to
allow
for
engine coolant expansion and contraction, during engine operation, without the
loss of coolant and without introducing air into the cooling system.
This coolant recovery tank should be installed
at,
or above, the engine's manifold level, in a location where
it can be easily
monttored and where coolant can be easily added if needed (see the figure below). A stain-
less steel mounting bracket is supplied with each ktt along with a 30-inch length
of
clear plastic hose and
clamps
to
connectthe hose between the engine's manifold fitting
to
the hose spud on the base
of
the recovery
tank.
COOLANT RECOVERY
TANK
\
'.;
\
'.'-,
f t
I'
'.
'
'i'~
\
"r
,','
"
.,'
\
J..
,,\.
,\
, \
,.
/,
, ,
Coolant Recovery Tank, Recommended Installation
49
Westerbeke Generators